"The accuracy of the laboratory in an industrial environment"

The characteristics of this automatic filling machine include: Dosing accuracy + / - 5 mg, automatic removal of doses that are not in the range of tolerance (for a total compliance of the filling), automatic positioning of the tubes and check to prevent two feeding in the same tube.
Range of operation:

Description / pictures:
Results : Set point: 130 mg, standard deviation: 1.12 mg

|
 |
Despite a disturbing environment for a high precision measurement (balance resolution: 0.1 mg), the results are remarkably accurate and stable (less than 2% of doses are out of tolerance). All out of tolerance doses, are automatically rejected in a container for recycling. Traceability of the results on Excel sheet, provides a quick analysis of performance.
|